Overview

This article is for customers of BreastScreen NSW and Best Practice. The focus of this article is configuring practice software result import acknowledgements to BreastScreen NSW so they know Best Practice has imported the messages.

Configuration

Ack Path
 


  1. To launch the HL7 Tray application, Go to Start Menu, All Programs, Medical-Objects and select the Medical-Objects Capricorn. Alternatively, You can go to C:\MO\Capricorn and run the Capricorn.exe.
     
  2. The following icon will appear in the tray. Double click on it to bring up the log window.



  3. When the log window is displayed, Click on the Configuration icon highlighted below, or select Utility and select Configuration.

     

Capricorn Configuration Settings

  1. Click on Integration Options.



  2. Note the path set in ACK Management.
     

  3. Open the Best Practice software.



  4. Click Setup from the toolbar shown above.

  5. Click on Configuration from the drop down menu.
     


  6. The Configuration window should be displayed.

  7. Select Results Import from the left panel. 

  8. Select the Add button under Acknowledgements shown below.



  9. The Send Acknowledgements window will appear.

  10. Add BreastScreen NSW as the Facility name (include the space).
     


  11. Click the file browse button to select the folder that was configured in Medical-Objects Capricorn in step 2. Use a UNC path version if you know it.

    eg: \\PC3\Results\BP\Acks

     


     

  12. Once you have selected the path click OK.

  • No labels