Overview

This guide will instruct you provides a basic overview on how to set up configure the Medical-Objects Download Client (Capricorn) to import drop off results for CompuDoc softwareCompudoc software.

If you require any assistance with the installation or configuration, or if you have any questions, please contact the Medical-Objects Helpdesk on (07) 5456 6000.

If you have not Installed the Medical-Objects Download client, Please see the guide for Installing Capricorn on Windows.

Finding the CompuDoc File path

  1. Open Compudoc on the server, and choose Tools, and then click Options.
     

     
  2. Click on the Locations box on the right hand side.


     
  3. Here you can see the file path that CompuDoc is set to pick up the results from. 

    Info
    titleNote:

    If there is no path chosen in the Location tab, then choose the default path C:\Compudoc\Pathology.


Configuring the Capricorn

 

Accessing the Capricorn Configuration Window

Info
titleNote:

In some cases, the Capricorn may be configured as a service. See this guide for instructions on how to launch the Capricorn if it is set up as a service. 


Excerpt Include
How to access Capricorn Configuration
How to access Capricorn Configuration
nopaneltrue

Capricorn Configuration Settings


  1. Double click the HL7 tray icon.
    Image Removed
    The log window is displayed.
    Image Removed
    Click the Edit Server Properties icon.
    Image Removed
    Click on Integration Options in the left hand side panel.
    Image Removed
    Tick the boxes Convert to PIT and Preserve Sending Facility in PIT.
    Make sure the Incoming Modifier is set to Capricorn Modifier.

    Click on Ack Management

    Image Added



    The Ack Management path should be set

    to

    as follows:

    No Format
    C:\MO\Capricorn\APPLICATION_ACKS


  2. Click on Integration Options.
    2.1   Check that the Incoming Modifier is set to Capricorn Modifier. 
    2.2 Tick the boxes Convert to PIT and Preserve Sending Facility in PIT.

    Image Added
     

  3. Click on Server Parameters in the left hand panel.

    Image Modified

    The Message Output Directory to the import directory for CompuDoc outlined in the previous instructions. For this example, we’ll use the following:

    No Format
    C:\Compudoc\Pathology
    .


    The configuration is complete. Compudoc should automatically begin importing results.

 