Overview

This guide provides a basic overview on how to configure the Medical-Objects Download Client (Capricorn) to drop off results for Compudoc software.

If you require any assistance with the installation or configuration, or if you have any questions, please contact the Medical-Objects Helpdesk on (07) 5456 6000.

If you have not Installed the Medical-Objects Download client, Please see the guide for Installing Capricorn on Windows.

Finding the CompuDoc File path

  1. Open Compudoc on the server, and choose Tools, and then click Options.
     

     
  2. Click on the Locations box on the right hand side.


     
  3. Here you can see the file path that CompuDoc is set to pick up the results from. 

    Note:

    If there is no path chosen in the Location tab, then choose the default path C:\Compudoc\Pathology.

Configuring the Capricorn

Accessing the Capricorn Configuration Window

Note:

In some cases, the Capricorn may be configured as a service. See this guide for instructions on how to launch the Capricorn if it is set up as a service. 


  1. To launch the HL7 Tray application, Go to Start Menu, All Programs, Medical-Objects and select the Medical-Objects Capricorn. Alternatively, You can go to C:\MO\Capricorn and run the Capricorn.exe.
     
  2. The following icon will appear in the tray. Double click on it to bring up the log window.



  3. When the log window is displayed, Click on the Configuration icon highlighted below, or select Utility and select Configuration.

     

Capricorn Configuration Settings


  1. Click on Ack Management



    The Ack Management path should be set as follows:

    C:\MO\Capricorn\APPLICATION_ACKS
  2. Click on Integration Options.
    2.1   Check that the Incoming Modifier is set to Capricorn Modifier. 
    2.2 Tick the boxes Convert to PIT and Preserve Sending Facility in PIT.


     

  3. Click on Server Parameters in the left hand panel.



    The Message Output Directory to the import directory for CompuDoc outlined in the previous instructions. For this example, we’ll use the following:

    C:\Compudoc\Pathology


    The configuration is complete. Compudoc should automatically begin importing results.