Overview

This guide will instruct you on how to set up the Medical Objects Capricorn to import results for CompuDoc software.

Finding the CompuDoc File path

  1. Open Compudoc on the server, and choose Tools, and then click Options.
     

     
  2. Click on the Locations box on the right hand side.


     
  3. Here you can see the file path that CompuDoc is set to pick up the results from. 

Configuring the Capricorn

 

  1. Double click the HL7 tray icon.



  2. The log window is displayed.



  3. Click the Edit Server Properties icon.



  4. Click on Integration Options in the left hand side panel.



    Tick the boxes Convert to PIT and Preserve Sending Facility in PIT.
    Make sure the Incoming Modifier is set to Capricorn Modifier.
    The Ack Management path should be set to C:\MO\Capricorn\APPLICATION_ACKS.
     
  5. Click on Server Parameters in the left hand panel.



    The Message Output Directory to the import directory for CompuDoc outlined in the previous instructions. For this example, we’ll use C:\Compudoc\Pathology.


    The configuration is complete. Compudoc should automatically begin importing results.

 