This guide provides instruction on configuring both Medical-Objects Capricorn and Best Practice software to import electronic results.
If you require any assistance with the installation or configuration, or if you have any questions, please contact the Medical-Objects Helpdesk on (07) 5456 6000.
If you have not Installed the Medical-Objects Download client, Please see the guide for Installing Capricorn on Windows.
If you have not done so already please confirm you have followed the instructions here before proceeding
In some cases, the Capricorn may be configured as a service. See this guide for instructions on how to launch the Capricorn if it is set up as a service. |
Click on Ack Management.
Set the Folder for Acks created by this practices PMS path to the ACK path related to the base path chosen in step 1.
Suggested:
C:\MO\Results\Ack |
Set the Folder to save external Acks for PMS path to the IN path related to the base path chosen in step 1.
Suggested:
C:\MO\Results\In |
If the folder does not exist, you must create it. Make sure the results folder has Modify, Read and Write permissions, AND is shared on the Network. |
Click on Integration Options.
3.1 Check that the Incoming Modifier is set to Best Practice.
Select Server Parameters from the left panel.
Under the Message Output Directory (main) set the results import path.
The recommended Import path is:
C:\MO\Results\In |
If the folder does not exist, you must create it.
Make sure the results folder has Modify, Read and Write Permissions, AND is shared on the Network.
The configuration is complete. Click Apply and OK.