Overview

MedTech 32 will already be configured to import results. All that is required is setting up the Medical-Objects download client to drop off results to the correct location. 

Configure Capricorn Software

  1. Double click the HL7 tray icon



  2. The log window will be displayed.



  3. Click the Edit Server Properties icon.


     
  4. Click on the Integration Options field on the left hand side.



  5. Set the Ack Management path to the local import folder on the server or the network path on a workstation that points to the server import folder, For example

    (Capricorn installed on the server) --> C:\Medtech32\Acks\

    (Capricorn installed on the Workstation) --> \\server\Medtech32\Acks\
     
  6. Click on Server Parameters in the left hand side panel.


     
  7. Under the Message Output Directory (Main) set the results import path.

    C:\Medtech32\HL7\In

    (Capricorn installed on the server) --> C:\Medtech32\HL7\In

    (Capricorn installed on the Workstation) --> \\server\Medtech32\HL7\In

  8. Click Apply / OK 
     
  9. Medical-Objects is now configured to import into MedTech32.