Overview

This guide provides a basic overview on configuring the Medical-Objects Download Client (Capricorn) and GPComplete Practice software to import electronic results.
 

If you require any assistance with the installation or configuration, or if you have any questions, please contact the Medical-Objects Helpdesk on (07) 5456 6000.


If you have not Installed the Medical-Objects Download client, Please see the guide for Installing Capricorn on Windows.

Configuring Capricorn Software


Accessing the Capricorn Configuration Window
 


  1. To launch the HL7 Tray application, Go to Start Menu, All Programs, Medical-Objects and select the Medical-Objects Capricorn. Alternatively, You can go to C:\MO\Capricorn and run the Capricorn.exe.
     
  2. The following icon will appear in the tray. Double click on it to bring up the log window.



  3. When the log window is displayed, Click on the Configuration icon highlighted below, or select Utility and select Configuration.

     

Capricorn Configuration Settings

 

  1. Click on Integration Options.



  2. Set the ACK Management path as below:

    (Capricorn installed on a GPComplete Server Machine) --> C:\Program Files\GPComplete\Service\Acksent\
    
    (Capricorn installed on a GPComplete Client Machine) --> \\server\GPComplete\Service\Acksent\
    



  3. Check that the Incoming Modifier is set to Capricorn Modifier.



  4. Select Server Parameters from the left panel.



    The paths above are set as follows:

    (Capricorn installed on a GPComplete Server Machine) -->

    Message Output Directory: C:\Program Files\GPComplete\Service\RecFiles\
    


    (Capricorn installed on a GPComplete Client Machine) -->

    Message Output Directory: \\server\GPComplete\Service\RecFiles\
  5. The Medical-Objects configuration is complete. Click Apply and OK.

Importing Into GPComplete

GPComplete does not require any configuration to import results. Below are the steps to manually import results.

  1. Open the GPComplete main window.


     
  2. Choose Administration and select Pathology from the top menu.



  3. From the Pathology menu click on Download Results and then In Tray.



If the results haven’t been imported into the In Tray, you may need to close the In Tray and reopen it to allow it to refresh and list the imported results.