Overview

This guide provides instruction on configuring both Medical-Objects Capricorn and MedTech32 software to send electronic results. This step is designed to be included in the Capricorn configuration for Medtech32 here.

If you require any assistance with the installation or configuration, or if you have any questions, please contact the Medical-Objects Helpdesk on (07) 5456 6000.

If you have not Installed the Medical-Objects Download client, Please see the guide for Installing Capricorn on Windows.

Configuring Capricorn Software 

Accessing the Capricorn Configuration Window
 


  1. To launch the HL7 Tray application, Go to Start Menu, All Programs, Medical-Objects and select the Medical-Objects Capricorn. Alternatively, You can go to C:\MO\Capricorn and run the Capricorn.exe.
     
  2. The following icon will appear in the tray. Double click on it to bring up the log window.



  3. When the log window is displayed, Click on the Configuration icon highlighted below, or select Utility and select Configuration.

     

Capricorn Configuration Settings

  1. Click on Manage Queues in the left hand panel, and click the Add button highlighted below. 



  2. Give the queue the name: MEDTECH32 SEND.
     

     
  3. Set the base directory to C:\MO\Capricorn\Queues\Medtech\
     

  4. Click OK.
     

  5. Click the Setup button highlighted below.



  6. Click Add, and add the following fields. 

    Fix Bad Escape Sequences in OBX FT
    Fix REF message
    Append Sending Facility to Report Title
    Route with Capricorn 
  7. Click Apply and OK

MedTech32 Configuration

  1. Open the MedTech32 software. In the toolbar, Select Tools > Message Transfer > Message Transfer Utility.
     

     
  2. Double click on the Medical-Objects entry. 


     
  3. Set the File Send Path to the Base Directory path set for the sending queue created earlier. Example: C:\MO\Capricorn\Queues\Medtech\.

    The configuration for MedTech Sending should now be complete.

Updating the Medtech32 Address book

to ensure that messages are delivered correctly, You will need to make sure the provider addressbook is up to date. The following guide explains how to do this using the Medical Objects Provider lookup.

 

  1. In your web browser, navigate to http://ph.med.net.au. On this page you can look up the providers that you want to send to by either name or postcode. There are instructions at the top of the page for how to run the search. Find the provider number of the recipient that you are wanting to send to and make sure they have True in the Is Active and Is Current columns. If they meet this criteria copy their provider number in preparation for step 2



  2. Once you have the provider number, return to your Medtech32 application. Click on Setup, Agencies and select Address Book. 



  3. Search for the doctor you wish to send to. Double click their name or select the highlighted button to edit their details.



  4. The following window will appear. Select the highlighted More Tab
     


  5. Enter the provider number from the Provider lookup in the Provider number feild.
     


  6. Click OK to save your changes.

 