Overview

This guide provides instruction on configuring both Medical-Objects Capricorn and MedTech32 to import electronic results.

If you require any assistance with the installation or configuration, or if you have any questions, please contact the Medical-Objects Helpdesk on (07) 5456 6000.

If you have not Installed MedTech 32 will already be configured to import results. All that is required is setting up the Medical-Objects download client to drop off results to the correct location. 

Configure Capricorn Software

Download client, Please see the guide for Installing Capricorn on Windows.

Configuring Capricorn Software 

Accessing the Capricorn Configuration Window
 

Info
titleNote:

In some cases, the Capricorn may be configured as a service. See this guide for instructions on how to launch the Capricorn if it is set up as a service. 


Excerpt Include
How to access Capricorn Configuration
How to access Capricorn Configuration
nopaneltrue

Capricorn Configuration Settings

  1. Click on Ack Management.

    Image AddedDouble click the HL7 tray icon
    Image Removed
    The log window will be displayed.
    Image Removed
    Click the Edit Server Properties icon.
    Image Removed
     Click on the Integration Options field on the left hand side.
    Image Removed

  2. Set the Ack Management path to the local import folder on the server or the network path on a workstation that points to the server import folder, For example:

    No Format
    (Capricorn installed on the server) --> C:\Medtech32\Acks\

    
    
    (Capricorn installed on the Workstation) --> \\server\Medtech32\Acks\

     


  3. Click on Integration Options.
    3.1 Check that the Incoming Modifier is set to MedTech32

    Image Added
  4. Click on Server Parameters in the left hand side panel.
    Image Removed

     Image Added

  5. Under the Message Output Directory (Main) set the results import path.

    C:\Medtech32\HL7\In


    No Format
    (Capricorn installed on the server)      --> C:\Medtech32\HL7\In

    
    
    (Capricorn installed on the Workstation) --> \\server\Medtech32\HL7\In
    


  6. Click Apply / OK 
     
    Medical-Objects is now configured to import into MedTech32.OK. Capricorn configuration is complete.

MedTech32 Configuration

  1. Open the MedTech32 software. In the toolbar, Select Tools > Message Transfer > Message Transfer Utility.

    Image Added

  2. Select the Add New Configuration button highlighted below.

    Image Added
  3. This will open the New Configuration window. In  Description, Type Medical-Objects. make sure that the File Format is set to HL7(H).

    Image Added
  4. You will want to configure the file paths to the correct folder:

    No Format
    File Recieved Path:       -->  C:\Medtech32\HL7\In
    Received File backup Path -->  C:\Medtech32\HL7\Bac
    Rejected File Backup Path -->  C:\Medtech32\HL7\Reje

     

    For Medtech Evolution, Please use the C:\Mo\Results\... directory. Make sure you are using UNC paths. 

    No Format
    File Recieved Path        -->  \\server\Mo\Results\In
    Received File backup Path -->  \\server\Mo\Results\Bac
    Rejected File Backup Path -->  \\server\Mo\Results\Reje


    Done correctly, It should look like the image below. 

    Image Added

  1. You should see Medical-Objects in the Message Transfer Utility List. Click the process button to import.

    Image Added

Info
titleNote:

Please note that you will also need to configure the Import paths and the scheduler on the Server. Please see this guide on how to do this.

Viewing Imported Results

Module → Inbox → Provider Inbox

Image Added

Choose the filter button and set the date range and Attention field (it may be best to set this to "All(*)").

Image Added

Image Added