Versions Compared
Key
- This line was added.
- This line was removed.
- Formatting was changed.
Overview
This guide provides instruction on configuring both Medical-Objects Capricorn and MedTech32 to import electronic results.
If you require any assistance with the installation or configuration, or if you have any questions, please contact the Medical-Objects Helpdesk on (07) 5456 6000.
If you have not Installed MedTech 32 will already be configured to import results. All that is required is setting up the Medical-Objects download client to drop off results to the correct location.
Configure Capricorn Software
Download client, Please see the guide for Installing Capricorn on Windows.
Configuring Capricorn Software
Accessing the Capricorn Configuration Window
Excerpt Include | ||||||
---|---|---|---|---|---|---|
|
Capricorn Configuration Settings
Double click the HL7 tray iconImage Removed
The log window will be displayed.
Image Removed
Click the Edit Server Properties icon.
Image Removed
- Click on the Integration Options field on the left hand side.
Set the Ack Management path to the local import folder on the server or the network path on a workstation that points to the server import folder, For example:
No Format (Capricorn installed on the server) --> C:\Medtech32\Acks\
(Capricorn installed on the Workstation) --> \\server\Medtech32\Acks\
- Click on Server Parameters in the left hand side panel.
Image Removed
Image Added Under the Message Output Directory (Main) set the results import path.
C:\Medtech32\HL7\InNo Format (Capricorn installed on the server) --> C:\Medtech32\HL7\In
(Capricorn installed on the Workstation) --> \\server\Medtech32\HL7\In
- Click Apply / OK
Medical-Objects is now configured to import into MedTech32.OK. Capricorn configuration is complete.
MedTech32 Configuration
- Open the MedTech32 software. In the toolbar, Select Tools > Message Transfer > Message Transfer Utility.
Image Added - Select the Add New Configuration button highlighted below.
Image Added - This will open the New Configuration window. In Description, Type Medical-Objects. make sure that the File Format is set to HL7(H).
Image Added You will want to configure the file paths to the correct folder:
No Format File Recieved Path: --> C:\Medtech32\HL7\In Received File backup Path --> C:\Medtech32\HL7\Bac Rejected File Backup Path --> C:\Medtech32\HL7\Reje
For Medtech Evolution, Please use the C:\Mo\Results\... directory. Make sure you are using UNC paths.No Format File Recieved Path --> \\server\Mo\Results\In Received File backup Path --> \\server\Mo\Results\Bac Rejected File Backup Path --> \\server\Mo\Results\Reje
Done correctly, It should look like the image below.
Image Added
- You should see Medical-Objects in the Message Transfer Utility List. Click the process button to import.
Image Added
Viewing Imported Results
Module → Inbox → Provider Inbox
Image Added
Choose the filter button and set the date range and Attention field (it may be best to set this to "All(*)").
Image Added
Image Added
Table of Contents | ||||
---|---|---|---|---|
|