Overview

This guide provides a basic overview on configuring the Medical-Objects Download Client (Capricorn) and GPComplete Practice software to import electronic results. 

If you require any assistance with the installation or configuration, or if you have any questions, please contact the Medical-Objects Helpdesk on (07) 5456 6000.

If you have not Installed the Medical-Objects Download client, Please see the guide for Installing Capricorn on Windows.


Warning
titleWarning

Please note that GPComplete currently generates malformed acknowledgements. These acknowledgements should not be configured to be delivered by the Medical Objects network as they can cause major issues.

Configuring Capricorn Software

Accessing the Capricorn Configuration Window
 

Info
titleNote:

In some cases, the Capricorn may be configured as a service. See this guide for instructions on how to launch the Capricorn if it is set up as a service. 


Excerpt Include
How to access Capricorn Configuration
How to access Capricorn Configuration
nopaneltrue

Capricorn Configuration Settings

  1. Click on Integration OptionsAck Management.
    Image Removed
    Set the ACK Management path as below:
    No Format
    (Capricorn installed on a GPComplete Server Machine) --> C:\Program Files\GPComplete\Service\Acksent\
    
    (Capricorn installed on a GPComplete Client Machine) --> \\server\GPComplete\Service\Acksent\
    
    Image Added

  2. Due to current malformed acknowledgements error (See warning at top of page). Make sure the ACKManagement Path is blank. 

  3. Click on Integration Options. 
    3.1 Check that the Incoming Modifier is set to Capricorn Modifier.
    Image Removed GP Complete

    Image Added

  4. Select Server Parameters from the left panel.



    The paths above are set as follows:

    No Format
    (Capricorn installed on a GPComplete Server Machine) --> C:\Program Files\GPComplete\Service\RecFiles\
    
    
    (Capricorn installed on a GPComplete Client Machine) --> \\server\GPComplete\Service\RecFiles\


    Info
    titleNote:

    If the folder does not exist, You must create it.


  5. The Medical-Objects configuration is complete. Click Apply and OK.

Importing Into GPComplete

GPComplete does not require any configuration from Medical-Objects to import results. Below are the steps to manually import results.

  1. Open the GPComplete main window.
    Image Removed
    Image Added
     
  2. Choose Administration and select Pathology Reports from the top menu. Select Results and select Download Results.
    Image Removed
    From the Pathology menu click on Download Results and then
    Image Added

  3. Results will download into GPComplete. If there are no new results, the below message will show. Select Open InTray to view results.

    Image AddedIn Tray.
    Image Removed

If the results haven’t been imported into the In TrayInTray, you may need to close the In Tray InTray and reopen it to allow it to refresh and list the imported results.

Table of Contents
outlinetrue
stylenone