This guide provides instruction on configuring both Medical-Objects Capricorn and Audit4 software to import electronic results.
If you require any assistance with the installation or configuration, or if you have any questions, please contact the Medical-Objects Helpdesk on (07) 5456 6000.
If you have not Installed the Medical-Objects Download client, Please see the guide for Installing Capricorn on Windows.
In some cases, the Capricorn may be configured as a service. See this guide for instructions on how to launch the Capricorn if it is set up as a service. |
Set the ACK Management Receivers path as below:
(Capricorn installed on an Audit 4 Server machine ) --> C:\Inpath\MO\Acks (Capricorn installed on an Audit 4 client machine --> \\Server\Inpath\MO\Acks |
2.1 Check Export Application Acks.
2.2 Set the ACK Management Senders Only path as below:
(Capricorn installed on an Audit 4 Server machine ) --> C:\Inpath\MO\Acks\AcksIncoming (Capricorn installed on an Audit 4 client machine --> \\Server\Inpath\MO\Acks\AcksIncoming |
If the folder does not exist, you must create it. |
The paths above are set as follows:
(Capricorn installed on an audit 4 server machine) --> Message output directory C:\Inpath\MO Save pathology: C:\Inpath\MO\Labs Save Radiology: C:\inpath\mo\Labs Capricorn installed on an Audit4 Client machine --> Message output directory \\Server\Inpath\MO Save Pathology \\Server\Inpath\MO\Labs Save Radiology \\Server\Inpath\MO\Labs |
Make sure that Save All ORU In Pathology path is UNTICKED
If the folder does not exist, you must create it. |
It is important that these folders only exist on one PC (Usually always the server) as they can cause conflicts. |
You will need to contact the Software4Specialist Help-Desk so that they can configure Audit4 to Import the Letters and Lab results and the export of Acknowledgments.
Department: Support Contact Number: 1300 133 308 Organisation: Software for Specialists (Audit4) |
Audit4 will require the following Configuration:
(Capricorn installed on a Audit4 Server Machine) -->
i. Store Message in Folder: C:\Inpath\MO\Acks
(Capricorn installed on a Audit4 Client Machine) -->
ii. Store Message in Folder: \\Server\Inpath\MO\Acks
19. Click Apply and OK to save the Convert Acks Queue and return to the Managed Queue configuration Screen.
20. Click Apply and OK to save the current configuration and to exit the Capricorn configuration editor.
You have now completed the configuration for the Medical Objects Capricorn to download and send acknowledgements.