This guide provides instruction on configuring both Medical-Objects Capricorn and MedTech32 to import electronic results.
If you require any assistance with the installation or configuration, or if you have any questions, please contact the Medical-Objects Helpdesk on (07) 5456 6000.
If you have not Installed the Medical-Objects Download client, Please see the guide for Installing Capricorn on Windows.
In some cases, the Capricorn may be configured as a service. See this guide for instructions on how to launch the Capricorn if it is set up as a service. |
Set the Ack Management path to the local import folder on the server or the network path on a workstation that points to the server import folder, For example:
(Capricorn installed on the server) --> C:\Medtech32\Acks\ (Capricorn installed on the Workstation) --> \\server\Medtech32\Acks\ |
Under the Message Output Directory (Main) set the results import path.
(Capricorn installed on the server) --> C:\Medtech32\HL7\In (Capricorn installed on the Workstation) --> \\server\Medtech32\HL7\In |
You will want to configure the file paths to the correct folder:
File Recieved Path: --> C:\Medtech32\HL7\In Received File backup Path --> C:\Medtech32\HL7\Bac Rejected File Backup Path --> C:\Medtech32\HL7\Reje |
Done correctly, It should look like the image below.