This guide provides instruction on configuring both Medical-Objects Download Client (Capricorn) and Medical Spectrum software to import electronic results.
If you require any assistance with the installation or configuration, or if you have any questions, please contact the Medical-Objects Helpdesk on (07) 5456 6000.
If you have not Installed the Medical-Objects Download client, Please see the guide for Installing Capricorn on Windows.
In some cases, the Capricorn may be configured as a service. See this guide for instructions on how to launch the Capricorn if it is set up as a service. |
Make sure at the bottom of the panel that under Incoming Modifier that Spectrum HL7 Modifier is set, as shown below.
Older versions of Spectrum will NOT import ORU or HL7 files that have file names over 9 Characters long. It does not have this problem with PIT files , so be sure to convert the files to PIT. The 9 Character limit also affects file paths. so if your results are in a folder called INCOMING RESULTS for example. It will not look in that path. |
In Message Output Directory (Main), Enter the path for letters to be imported in to. For example:
C:\MO\Letters\ |
Enter the Pathology and Radiology paths as shown above.
Pathology - C:\MO\Path Radiology - C:\MO\Rad |
Enter MO in the Id Number field and press TAB.
Make sure you backspace to the left in the ID Number field to avoid blanks; you cannot delete an entry once it has been created. If MO is already configured, press TAB to call up the details. You can also select Medical-Objects from the available drop down list; this will display the ID Number only. Press TAB to call up the details. |
Select Medical-Objects Letters, Medical-Objects Pathology, or Medical-Objects Radiology to see what results have arrived.
If there are any results, the number of results imported will show. If there are no results, this number will be 0. |
Click OK.
You should now be back to the main window. |