This guide provides instruction on configuring the Medical-Objects Download Client (Capricorn) to output HL7 Results to a set folder.
If you require any assistance with the installation or configuration, or if you have any questions, please contact the Medical-Objects Helpdesk on (07) 5456 6000.
If you have not Installed the Medical-Objects Download client, Please see the guide for Installing Capricorn on Windows.
In some cases, the Capricorn may be configured as a service. See this guide for instructions on how to launch the Capricorn if it is set up as a service. |
Click on Ack Management.
Set the ACK Management path to C:\MO\Capricorn\APPLICATION_ACKS
3.1 Set the Incoming Modifier to Capricorn Modifier as shown below.
Alternatively the field can be left blank for a messages to be delivered as close to they were originally sent as possible. |
Under the Message Output Directory (main), set the results import path.
The path will be a folder you want to use to store the Hl7 results or messages that you receive.
For this installation we will just create a folder in the C: drive called Medical Results.
The file path in this case will be C:\Medical Results.
Press the Apply button when configurations are complete. All future messages will be delivered to this folder in HL7 format.