This guide provides instruction on configuring both Medical-Objects Capricorn and older versions of Best Practice software to import electronic results.
If you require any assistance with the installation or configuration, or if you have any questions, please contact the Medical-Objects Helpdesk on (07) 5456 6000.
If you have not Installed the Medical-Objects Download client, Please see the guide for Installing Capricorn on Windows.
In some cases, the Capricorn may be configured as a service. See this guide for instructions on how to launch the Capricorn if it is set up as a service. |
Click on Ack Management.
Set the ACK Management path to the C: Drive, For example:
C:\MO\Results\BP\Acks |
If the folder does not exist, you must create it. Make sure the results folder has Modify, Read and Write permissions, AND is shared on the Network. |
Click on Integration Options.
3.1 Check that the Incoming Modifier is set to Best Practice.
Select Server Parameters from the left panel.
Under the Message Output Directory (main) set the results import path.
The recommended Import path is:
C:\MO\Results\BP\In |
If the folder does not exist, you must create it.
Make sure the results folder has Modify, Read and Write Permissions, AND is shared on the Network.
The configuration is complete. Click Apply and OK.
Best Practice import and acknowledgement file path configuration MUST be completed on the server (Machine that runs BP Link). |
RDP Connections must NOT be used to configure import and acknowledgement file paths in Best Practice, as Best Practice may interpret the settings as being entered from the PC which the RDP session was created from. |
On the System Information window, please locate the following items from the left hand list and make sure their corresponding value is correct.
Installation Type = Server
Database Server = (local)
Remote Session = False
If you are unable to locate or connect to Best Practice on the server in the console session, Please contact your IT Support personnel or call the Best Practice Helpdesk on (07) 4155 8800. Do NOT continue configuration if you are unable to access the server. |
If possible, Use a UNC path.
eg: \\PC3\Results\BP\In |
Click the file browse button to select the folder that was configured in Medical-Objects Capricorn earlier. Again, Use a UNC path if you can.
eg: \\PC3\Results\BP\Acks |
Click Save to save and close the window.
The acknowledgement process from step 10 to 16 will have to be repeated for each additional sending facility that requires acknowledgements. The path will stay the same but the facility name will change. |
Please Note: The Best Practice application (BP Link) must be running for Best Practice to be able to import results. If you require any assistance locating or starting the BP Link application, Please call the Best practice Helpdesk on (07) 4155 8800. |