Overview

This guide provides an overview on configuring the Medical-Objects Download Client (Capricorn) and Genie Software to import electronic results. This process is based on the Microsoft Windows environment.

If you require any assistance with the installation or configuration, or if you have any questions, please contact the Medical-Objects Helpdesk on (07) 5456 6000.

If you have not Installed the Medical-Objects Download client, Please see the guide for Installing Capricorn on Windows.

Genie Auto import Pre-Configuration Check

Prior to installing the Medical-Objects Capricorn, the following must be checked and the installation performed accordingly to allow Genie to automatically import the results received via Medical-Objects.

 

  1. Log into Genie and click on File, and select Practice Preferences.



  2. Select the Practice whose configuration you want to check.




  3. On the Practice Configuration window, Find the practice that you want to check the auto-import settings for in the clinic name column and double click the entry.

  4. In the Edit Practice Preferences window, click on the Clinical tab.
    Note the checkboxes named Allow Pathology Import on Server and Import Pathology Automatically on Client.

 


Example: As we can see in the screenshot below Genie is set to import results on the Server, If you are required to install the Medical-Objects Capricorn on a Genie client workstation then it must be set to download the results across the network to the Genie server to allow Genie to automatically import the downloaded results.

If Genie is set to import from the server and results are downloaded to a workstation, then a manual import must be run from the Genie client installed on the workstation where the results are downloaded and vise versa.

Capricorn Configuration


Accessing the Capricorn Configuration Window

 

  1. To launch the HL7 Tray application, Go to Start Menu, All Programs, Medical-Objects and select the Medical-Objects Capricorn. Alternatively, You can go to C:\MO\Capricorn and run the Capricorn.exe.
     
  2. The following icon will appear in the tray. Double click on it to bring up the log window.



  3. When the log window is displayed, Click on the Configuration icon highlighted below, or select Utility and select Configuration.

     

Capricorn Configuration Settings

  1. Click on Integration Options.
     

     
  2. Set the ACK Management path as below:

    (Capricorn installed on a Genie Server Machine) --> C:\Genie\Labrslts\Hl7 ACKS
    (Capricorn installed on a Genie Client Machine) --> \\server\Genie\Labrslts\Hl7 ACKS\
  3. Check that the Incoming Modifier is set to Genie REF.
     

     
  4. Select Server Parameters from the left panel.
     

     
  5. The paths above are set as follows:

    (Capricorn installed on a Genie Server Machine) -->

    Message Output Directory --> C:\Genie\Labrslts\
    Save Pathology           --> C:\Genie\Labrslts\
    Save Radiology           --> C:\Genie\Labrslts\


    (Capricorn installed on a Genie Client Machine) -->

     

    Message Output Directory --> \\server\Genie\Labrslts\
    Save Pathology           --> \\server\Genie\Labrslts\
    Save Radiology           --> \\server\Genie\Labrslts\

     

    Make Sure that Save all ORU in Pathology Path is UNTICKED

  6. The Medical-Objects configuration is complete. Click Apply and OK.