Should you require any more information or have encountered a problem, please call the support helpdesk on (07) 5456 6000.

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 12 Next »

This guide may be OUTDATED. Screenshots will need to be updated and some information may no longer be correct.

Overview

This guide provides an overview of setting up the Medical-Objects Download client to import into VIP software.

Capricorn Configuration


  1. Double click the HL7 tray icon. 



    If the Capricorn HL7 tray icon is not visible, open Capricorn from Start Menu > All Programs > Medical-Objects > Medical Objects Capricorn or from the C:\MO\Capricorn\Capricorn.exe.
  2. The Log window is displayed.

  3. Click the Edit Server Properties icon.



  4. Click on Integration Options.


     
  5. Leave the ACK Management path as default, Which should be:

    C:\MO\Capricorn\APPLICATION_ACKS
  6. Select Server Parameters from the left panel.



  7. Under Message Output Directory (main), set the results import path to the drive the results are stored on.

    For Example: 
    Main Directory -  X:\Labs\MO


    By Default, Everything will be imported under the Medical-Objects contact explained later in this guide.
    However, If the site requires the files to show up as the Pathology/Radiology sender (i.e QHPS/SXR) you will need to set Message Source Exceptions  and divert those specific files to another path.

    Pathology -  X:\Labs\MO\QHPS Radiology -  X:\Labs\MO\SXR

     
  8. Select Message Src Exceptions from the left hand panel of the Capricorn configuration window.



  9. Click Add as shown above, and select Lookup Sending Facility HD. Do not use any other selection.



  10. A new window will appear called Select Identifier.


     
  11. Enter Southern and press Enter or click the Lightning Bolt to search.

  12. Select Southernex Imaging from the display panel.|
     
  13. The following Message Source Exception window will appear.



  14. Click OK to leave all the details blank.

  15. Repeat this step for each of the Contacts that were setup in Practix (e.g. In this case QHPS (Nata 2639) and Southernex Imaging).


The configuration is complete. Click Apply and OK. 

 


Setup VIP to Import

 

  1. From the top Menu, choose Patient, and then Search.

  2. Perform a search for your company, such as 'medical' to see if a contact currently exists for Medical-Objects.



  3. To create the contact, tick the 'New Organisation' box and choose search.



  4. Click 'New' button in bottom left hand corner of screen that appears.



  5. Put company name e.g 'Medical Objects' in the name section and choose role. e.g 'Laboratory'. Put short name - e.g 'MO' in the code box.



  6. Click the 'Investigations Provider Details' tab. for 'Receiving Directory' put in the path you set the Capricorn to output the files to. If you used a message source exception to direct certain Pathology/Radiology companies to a different folder, you will have to put this folder name for that contact. Be sure to choose the correct results format HL7 or Pit.



  7. Click OK. VIP should now pickup the files.

 

  • No labels