Overview

This guide provides instruction on configuring both Medical-Objects Capricorn and Audit4 software to import electronic results.

If you require any assistance with the installation or configuration, or if you have any questions, please contact the Medical-Objects Helpdesk on (07) 5456 6000.

If you have not Installed the Medical-Objects Download client, Please see the guide for Installing Capricorn on Windows.

Configuring Capricorn Software 

Accessing the Capricorn Configuration Window
 


  1. To launch the HL7 Tray application, Go to Start Menu, All Programs, Medical-Objects and select the Medical-Objects Capricorn. Alternatively, You can go to C:\MO\Capricorn and run the Capricorn.exe.
     
  2. The following icon will appear in the tray. Double click on it to bring up the log window.



  3. When the log window is displayed, Click on the Configuration icon highlighted below, or select Utility and select Configuration.

     

Capricorn Configuration Settings

  1. Click on Integration Options.


     
  2. Set the ACK Management Receivers path as below: 

    (Capricorn installed on an Audit 4 Server machine ) -->		C:\Inpath\MO\Acks
    
    (Capricorn installed on an Audit 4 client machine --> 		\\Server\Inpath\MO\Acks

    2.1 Check Export Application Acks

    2.2 Set the ACK Management Senders Only path as below: 

    (Capricorn installed on an Audit 4 Server machine ) -->		C:\Inpath\MO\Acks\AcksIncoming
    
    (Capricorn installed on an Audit 4 client machine --> 		\\Server\Inpath\MO\Acks\AcksIncoming
  3. Check that the Incoming Modifier is set to Audit4.


     
  4. Select Server Parameters from the left panel.



  5. The paths above are set as follows

    (Capricorn installed on an audit 4 server machine) --> 
    
    Message output directory 						 C:\Inpath\MO
    Save pathology: 								 C:\Inpath\MO\Labs
    Save Radiology: 								 C:\inpath\mo\Labs
    
    Capricorn installed on an Audit4 Client machine -->
    Message output directory 						  \\Server\Inpath\MO
    Save Pathology 									  \\Server\Inpath\MO\Labs
    Save Radiology 									  \\Server\Inpath\MO\Labs
  6. Make sure that Save All ORU In Pathology path is UNTICKED



  7. Select Manage Queues from the left panel. Complete the Manage Queues section.

Software for Specialists (Audit4) Configuration.


You will need to contact the Software4Specialist Help-Desk so that they can configure Audit4 to Import the Letters and Lab results and the export of Acknowledgments.


Department: Support
Contact Number: 1300 133 308
Organisation: Software for Specialists (Audit4)


Audit4 will require the following Configuration: 

  1. Letters are to be imported from: C:\Inpath\MO\Letters
     
    Or as defined by the Convert Letters to REF queue’s Store Message in folder decorator (See step 13)
     
  2. Lab results are to be imported from: C:\Inpath\MO\Labs
     
  3. Acknowledgements are to be exported to: C:\Inpath\MO\Acks\ConvertAck

    Or as defined by the Base directory for the ConvertACK Queue (see step 17)


(Capricorn installed on a Audit4 Server Machine) -->

i.      Store Message in Folder:              C:\Inpath\MO\Acks
 
(Capricorn installed on a Audit4 Client Machine) --> 
 
ii.     Store Message in Folder:              \\Server\Inpath\MO\Acks


19.  Click Apply and OK to save the Convert Acks Queue and return to the Managed Queue configuration Screen.

20. Click Apply and OK to save the current configuration and to exit the Capricorn configuration editor.

You have now completed the configuration for the Medical Objects Capricorn to download and send acknowledgements.