Overview

This guide provides instruction on configuring both Medical-Objects Capricorn and Shexie software to import electronic results. This process is based on a Windows XP environment.

If you require any assistance with the installation or configuration, or if you have any questions, please contact the Medical-Objects Helpdesk on (07) 5456 6000.

If you have not Installed the Medical-Objects Download client, Please see the guide for Installing Capricorn on Windows.
 

Configuring Capricorn Software 

Accessing the Capricorn Configuration Window

 

  1. To launch the HL7 Tray application, Go to Start Menu, All Programs, Medical-Objects and select the Medical-Objects Capricorn. Alternatively, You can go to C:\MO\Capricorn and run the Capricorn.exe.
     
  2. The following icon will appear in the tray. Double click on it to bring up the log window.



  3. When the log window is displayed, Click on the Configuration icon highlighted below, or select Utility and select Configuration.

     

Capricorn Configuration Settings

  1. Click on the Integration Options.


     
  2. Set the ACK Management path to the local Import folder on the server or the network path on a workstation, that points to the server import folder.
    For example:

    Acknowledgement paths in Shexie

    (Capricorn installed on the Server) --> C:\Shexie\pathology\MoAcks
    Or
    (Capricorn installed on the Workstation) --> \\server\Shexie\pathology\MoAcks
    

    Integration Settings

    Set Tick Box to "Evaluate and Strip"
    Set Tick Box to "Convert to Pit"
    Set Tick Box to "Preserve Sending Facility in Pit"
    Set Incoming Modifier to "Shexie Modifier" 
     

  3. Select Server Parameters from the left panel.


     
  4. Under Message Output Directory (main) set the results import path.
     
  5. The path can be different depending on where Capricorn is installed.

    For example:

    Download paths in Shexie

    (Capricorn installed on the Server) --> C:\Shexie\pathology\
    Or
    (Capricorn installed on the Workstation) --> \\server\Shexie\pathology\


  6. The configuration is complete. Click Apply and OK.

Shexie Configuration

 

 

  1. To check Pathology results, go to the Housekeeping Tab and then select Pathology Results.


     
  2. This will then display the Pathology Results you have received.


     
  3. To check if Specialist or Allied health letters have arrived select E-Letters


     
  4. This will then display the E-Letters you have received.

     