Overview
Provide a guide to configure Medical-Objects Software with MedTech32.
Configure Capricorn Software
Double click the HL7 tray iconThis guide provides instruction on configuring both Medical-Objects Capricorn and MedTech32 to import electronic results.
If you require any assistance with the installation or configuration, or if you have any questions, please contact the Medical-Objects Helpdesk on (07) 5456 6000.
If you have not Installed the Medical-Objects Download client, Please see the guide for Installing Capricorn on Windows.
Configuring Capricorn Software
Accessing the Capricorn Configuration Window
The log window will be displayed.Click the Edit Server Properties icon.
Message Box | ||||||
---|---|---|---|---|---|---|
|
In some cases, the Capricorn may be configured as a service. See this guide for instructions on how to launch the Capricorn if it is set up as a service. |
Excerpt Include | ||||||
---|---|---|---|---|---|---|
|
Capricorn Configuration Settings
- Click on the Integration Options field on the left hand side.
Set the Ack Management path to the local import folder on the server or the network path on a workstation that points to the server import folder, For example:
No Format (Capricorn installed on the server) --> C:\Medtech32\Acks\
(Capricorn installed on the Workstation) --> \\server\Medtech32\Acks\
- Click on Server Parameters in the left hand side panel.
Under the Message Output Directory (Main) set the results import path.
No Format (Capricorn installed on the server) --> C:\Medtech32\HL7\In
(Capricorn installed on the Workstation) --> \\server\Medtech32\HL7\In
- Click Apply / OK. Capricorn configuration is complete.
MedTech32 Configuration
- Open the MedTech32 software. In the toolbar, Select Tools > Message Transfer > Message Transfer Utility.
- Select the Add New Configuration button highlighted below.
- This will open the New Configuration window. In Description, Type Medical-Objects. make sure that the File Format is set to HL7(H).
You will want to configure the file paths to the correct folder:
C:\MT32\MONo Format File Recieved Path:
- Rejected File backup Path: C:\MT32\Bac
--> C:\Medtech32\HL7\In
Received File backup Path --> C:\Medtech32\HL7\Bac
Rejected File Backup Path --> C:\Medtech32\HL7\Reje |
For Medtech Evolution, Please use the C:\Mo\Results\... directory. Make sure you are using UNC paths.
No Format |
---|
File Recieved Path --> \\server\Mo\Results\In
Received File backup Path --> \\server\Mo\Results\Bac
Rejected File Backup Path --> \\server\Mo\Results\Reje |

- You should see Medical-Objects in the Message Transfer Utility List. Click the process button to import.
Message Box | ||||||
---|---|---|---|---|---|---|
| ||||||
Please note that you will also need to configure the Import paths and the scheduler on the Server. Please see this guide on how to do this. |
Viewing Imported Results
Module → Inbox → Provider Inbox
Image Added
Choose the filter button and set the date range and Attention field (it may be best to set this to "All(*)").
Image Added
Image Added