Versions Compared
Key
- This line was added.
- This line was removed.
- Formatting was changed.
Overview
This guide is a guide to provide a basic overview of the configuration instructions for the Medical-Objects Download Client (Capricorn) to Import into Locum Software.This guide provides instruction on configuring both Medical-Objects Capricorn and Best Practice software to import electronic resultsdrop off electronic results for Locum software.
If you require any assistance with the installation or configuration, or if you have any questions, please contact the Medical-Objects Helpdesk on (07) 5456 6000.\
If you have not Installed the Medical-Objects Download client, Please see the guide for Installing Capricorn on Windows.
Configuring Capricorn Software
Accessing the Capricorn Configuration Window
Info | ||
---|---|---|
| ||
In some cases, the Capricorn may be configured as a service. See this guide for instructions on how to launch the Capricorn if it is set up as a service. |
Excerpt Include | ||||||
---|---|---|---|---|---|---|
|
Capricorn Configuration Settings
Select Integration Options from the left hand panelClick on Ack Management.
Image Removed
Image Added
Set the Ack Management path to the following:No Format C:\MO\Capricorn\APPLICATION_ACKS
Click on Integration Options.
2.1 Make sure the Incoming Modifier is set to Capricorn Modifier
2.2 Make sure Convert to PIT and Preserve Sending Facility in PIT is checked.
Image Added- Click on Server Parameters from the left hand panel.
Image Modified
Set the Message Output Directory (main) to the following:
No Format C:\Program Files\Locum3\PATHOLOGY\Unprocessed
- Click Apply and OK.
Locum should automatically import results.
Table of Contents | ||||
---|---|---|---|---|
|