Overview

This guide is guide to provide basic setup instructions a basic overview of the configuration for the Medical-Objects Download Client (Capricorn to Import into Locum Software.

 

) to drop off electronic results for Locum software.

If you require any assistance with the installation or configuration, or if you have any questions, please contact the Medical-Objects Helpdesk on (07) 5456 6000.

If you have not Installed the Medical-Objects Download client, Please see the guide for Installing Capricorn on Windows.

Configuring Capricorn Software 

Accessing the Capricorn Configuration Window
 

Info
titleNote:

In some cases, the Capricorn may be configured as a service. See this guide for instructions on how to launch the Capricorn if it is set up as a service. 


Excerpt Include
How to access Capricorn Configuration
How to access Capricorn Configuration
nopaneltrue

Capricorn Configuration Settings

  1. Double click the HL7 tray icon.
    Image Removed
    The Log window is displayed.
    Image Removed
    Click the Edit Server Properties icon.
    Image Removed 
     Select Integration Options from the left hand panel.
    Image Removed
     

    Click on Ack Management.

    Image Added



    Set the Ack Management path to the following:

    No Format
    C:\MO\Capricorn\APPLICATION_ACKS


  2. Click on Integration Options.
    2.1 Make sure the Incoming Modifier is set to Capricorn Modifier

     

    2.2 Make sure Convert to PIT and Preserve Sending Facility in PIT is checked.

     


    Image Added

  3. Click on Server Parameters from the left hand panel.

    Image Modified
     
  4. Set the Message Output Directory (main) to the following:

    No Format
    C:\Program Files\Locum3\PATHOLOGY\Unprocessed

     

  5. Click Apply and OK.


Locum should automatically import results.