Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Overview:

This guide provides instruction on configuring both Medical-Objects Capricorn and Best Practice software to import electronic results.

If you require any assistance with the installation or configuration, or if you have any questions, please contact the Medical-Objects Helpdesk on (07) 5456 6000.

If you have not Installed the Medical-Objects Download client, Please see the guide for Installing Capricorn on Windows.

Pre-Configuration Checks for Best Practice

If you have not done so already please confirm you have followed the instructions here before proceeding

Configuring Capricorn Software 

Accessing the Capricorn Configuration Window
 


Excerpt Include
How to access Capricorn Configuration
How to access Capricorn Configuration
nopaneltrue

Capricorn Configuration Settings

  1. Once a base path is determined, via either option a or b below, 2 directories are required; IN and ACK (These paths may already exist).
    1. If a base path for Medical Objects messaging has not been set in most cases C:\MO\Results\ can be used. This folder will need to be shared with read/write permissions on the network (Best Practice requires UNC paths for the import/export locations).
    2. If the Capricorn is already installed you will more likely use the current base path set. This path may already have a network share associated with it and can be confirmed using a command prompt and checking the listing of "net share" .

  2. Click on Ack Management.

    Set the Folder for Acks created by this practices PMS path to the ACK path related to the base path chosen in step 1.

    Suggested: 

    No Format
    C:\MO\Results\AcksAck

    Set the Folder to save external Acks for PMS path to the IN path related to the base path chosen in step 1.

    Suggested: 

    No Format
    C:\MO\Results\In





      

  3. Click on Integration Options.
    3.1 Check that the Incoming Modifier is set to Best Practice.



  4. Select Server Parameters from the left panel.



    Under the Message Output Directory (main) set the results import path.
     
    The recommended Import path is:


    No Format
    C:\MO\Results\In


    If the folder does not exist, you must create it.

    Make sure the results folder has Modify, Read and Write Permissions, AND is shared on the Network.


  5. The configuration is complete. Click Apply and OK.

Configuring Best practice to Import Results

  1. Open the Best Practice software.



  2. Click Setup from the toolbar shown above.
     
  3. Click on Configuration from the drop down menu.
     



  4. The Configuration window should be displayed.
     
  5. Select Results Import from the left panel.

    If any paths under Acknowledgements use the ACK path, in the Capricorn configuration above, they can be removed using the Remove button.
    If any paths under Report file search paths use the IN path, in the Capricorn configuration above, to be used for importing then they will need to be removed by choosing the Check paths button.

    Image Added
  6. Select the path/s that need to be deleted then choose Delete. Click Close when done.

    Image Added

Table of Contents
outlinetrue
stylenone