Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Overview

Provide a guide to configure Medical-Objects Software with MedTech32.

Configure Capricorn Software

Double click the HL7 tray icon
Image Removed
The log window will be displayed.
Image Removed

This guide provides instruction on configuring both Medical-Objects Capricorn and MedTech32 to import electronic results.

If you require any assistance with the installation or configuration, or if you have any questions, please contact the Medical-Objects Helpdesk on (07) 5456 6000.

If you have not Installed the Medical-Objects Download client, Please see the guide for Installing Capricorn on Windows.

Configuring Capricorn Software 

Accessing the Capricorn Configuration Window
 


Excerpt Include
How to access Capricorn Configuration
How to access Capricorn Configuration
nopaneltrue

Capricorn Configuration Settings

Click the Edit Server Properties icon.
Image Removed
 

  1. Click on the Integration Options field on the left hand side.



  2. Set the Ack Management path to the local import folder on the server or the network path on a workstation that points to the server import folder, For example:

    No Format
    (Capricorn installed on the server) --> C:\Medtech32\Acks\

    
    
    (Capricorn installed on the Workstation) --> \\server\Medtech32\Acks\

     
  3. Click on Server Parameters in the left hand side panel.

     

  4. Under the Message Output Directory (Main) set the results import path.

    No Format
    (Capricorn installed on the server)      --> C:\Medtech32\HL7\In

    
    
    (Capricorn installed on the Workstation) --> \\server\Medtech32\HL7\In
    
  5. Click Apply / OK. Capricorn configuration is complete.

MedTech32 Configuration

  1. Open the MedTech32 software. In the toolbar, Select Tools > Message Transfer > Message Transfer Utility.



  2. Select the Add New Configuration button highlighted below.


     
  3. This will open the New Configuration window. In  Description, Type Medical-Objects. make sure that the File Format is set to HL7 (H).


     
  4. You will want to configure the file paths to the correct folder:

    No Format
    File Recieved Path:
      C
           -->  C:\Medtech32\HL7\In
    
    Rejected File backup
    Path:  C
     Path -->  C:\Medtech32\HL7\Bac

    
    Rejected File Backup
    Path:  C
     Path -->  C:\Medtech32\HL7\Reje

      1.  
    Done correctly, It should look like the image below. 


     
  5. You should see Medical-Objects in the Message Transfer Utility List. Click the process button to import.

     

Table of Contents
outlinetrue
stylenone