This section includes instructions for setting up the Medical-Objects Capricorn for sending through Shexie. This step is designed to be included in the Capricorn configuration for Shexie Here.
If you require any assistance with the installation or configuration, or if you have any questions, please contact the Medical-Objects Helpdesk on (07) 5456 6000.
If you have not Installed the Medical-Objects Download client, Please see the guide for Installing Capricorn on Windows.
Configuring Capricorn Software
Accessing the Capricorn Configuration Window
Excerpt Include | ||||||
---|---|---|---|---|---|---|
|
Capricorn Configuration Settings
Click on Manage Queues in the left hand side panel.
Image Added
- Click Add.
Image Added
Set the Queue name to SHEXIE SENDING
Set the Base Directory to C:\Shexie\Letters\Medical Objects\
Click the OK button to save.
- Click the setup button.
- Click the add button and search for Specify File Mask.
- Set the file mask to HL7
- Add the following decorators using the previous steps.
- Override Sender HD to this Value (Add practice name and identifier
- Exapand rougting ID
- modify message with HL7 Script
- Script:
program FixResultStatus;
begin
if HL7Data['OBR.25.0'] = '' then
HL7Data['OBR.25'] := 'F';
end. Route with Capricorn.
Click the apply and OK buttons to save your settings.