Overview

This article is for customers of BreastScreen NSW and Best Practice. The focus of this article is configuring practice software result import acknowledgements to BreastScreen NSW so they know Best Practice has imported the messages.

Configuration

This is no longer needed if you have 1.11.1.934 and above of BP and have set up importing per the new setup instructions here.

Ack Path
 

In some cases, the Capricorn may be configured as a service. See this guide for instructions on how to launch the Capricorn if it is set up as a service. 


Capricorn Configuration Settings

  1. Click on Ack Management.



  2. Note the path set in ACK Management.
     

    If the folder does not exist, you must create it. Normally the default is C:\MO\Results\BP\Acks.

    Make sure the results folder has Modify, Read and Write permissions, AND is shared on the Network.


  3. Open the Best Practice software.



  4. Click Setup from the toolbar shown above.

  5. Click on Configuration from the drop down menu.
     


  6. The Configuration window should be displayed.

  7. Select Results Import from the left panel. 

  8. Select the Add button under Acknowledgements shown below.



  9. The Send Acknowledgements window will appear.

  10. Add BreastScreen NSW as the Facility name (include the space).
     


  11. Click the file browse button to select the folder that was configured in Medical-Objects Capricorn in step 2. If you know what a UNC path is; then it is advised you use a UNC path version if you know it for the folder noted in step 2.

    eg: \\PC3\Results\BP\Acks

     


     

  12. Once you have selected the path click OK.


  13. Exit the configuration confirming that you have made changes. Best Practice should now return the acknowledgements that BreastScreen NSW require.