Overview
Provide a guide to configure Medical-Objects Software with MedTech32.
Configure Capricorn Software
Double click the HL7 tray iconImage Removed
This guide provides instruction on configuring both Medical-Objects Capricorn and MedTech32 to import electronic results.
If you require any assistance with the installation or configuration, or if you have any questions, please contact the Medical-Objects Helpdesk on (07) 5456 6000.
If you have not Installed the Medical-Objects Download client, Please see the guide for Installing Capricorn on Windows.
Configuring Capricorn Software
Accessing the Capricorn Configuration Window
Excerpt Include | ||||||
---|---|---|---|---|---|---|
|
Capricorn Configuration Settings
The log window will be displayed.Image Removed
Click the Edit Server Properties icon.
Image Removed
- Click on the Integration Options field on the left hand side.
Set the Ack Management path to the local import folder on the server or the network path on a workstation that points to the server import folder, For example:
No Format (Capricorn installed on the server) --> C:\Medtech32\Acks\
\Acks(Capricorn installed on the Workstation) --> \\server\Medtech32
\
Select the Export Application Acks Checkbox. Set the Save External
path to C:Acks
External Acks\
- Click on Server Parameters in the left hand side panel.
Under the Message Output Directory (Main) set the results import path.
C:\Medtech32\HL7\InNo Format (Capricorn installed on the server) --> C:\Medtech32\HL7\In
(Capricorn installed on the Workstation) --> \\server\Medtech32\HL7\In
- Click Apply / OK. Capricorn configuration is complete.
MedTech32 Configuration
- Open the MedTech32 software. In the toolbar, Select Tools > Message Transfer > Message Transfer Utility.
- Select the Add New Configuration button highlighted below.
- This will open the New Configuration window. In Description, Type Medical-Objects. make sure that the File Format is set to HL7(H).
You will want to configure the file paths to the correct folder:
C:\MT32\MONo Format File Recieved Path:
--> C:\Medtech32\HL7\In Received File backup Path --> C:\Medtech32\HL7\Bac Rejected File Backup Path --> C:\Medtech32\HL7\Reje
For Medtech Evolution, Please use the C:\Mo\Results\... directory. Make sure you are using UNC paths.No Format File Recieved Path --> \\server\Mo\Results\In Received File backup Path --> \\server\Mo\Results\Bac Rejected File Backup Path --> \\server\Mo\Results\Reje
- Rejected File backup Path: C:\MT32\Bac
- You should see Medical-Objects in the Message Transfer Utility List. Click the process button to import.
Viewing Imported Results
Module → Inbox → Provider Inbox
Image Added
Choose the filter button and set the date range and Attention field (it may be best to set this to "All(*)").
Image Added
Image Added