Overview

This guide provides instruction on configuring both Medical-Objects Capricorn and VIP.net software to import electronic results.

If you require any assistance with the installation or configuration, or if you have any questions, please contact the Medical-Objects Helpdesk on (07) 5456 6000, or the VIP.net Helpdesk on (02) 9669 1844.

If you have not Installed the Medical-Objects Download client, Please see the guide for Installing Capricorn on Windows.

Configuring Capricorn Software 

Accessing the Capricorn Configuration Window

 


Excerpt Include
How to access Capricorn Configuration
How to access Capricorn Configuration
nopaneltrue
 

Capricorn Configuration Settings 

  1. Click on the Integration Options.


     

  2. Set the ACK Management path to the C: Drive, For example:


    No Format
    C:\MO\Results\VIP\Outgoing



  3. Check that the Incoming Modifier is set to VIP Modifier.



  4. Select Server Parameters from the left panel.


     

  5. Under the Message Output Directory (main) set the results import path.

    The recommended Import path is:


    No Format
    C:\MO\Results\VIP\Incoming


    However if you wish to separate Pathology and Radiology, Set the following paths accordingly.

    No Format
    Pathology - C:\MO\Results\VIP\Path
    Radiology - C:\MO\Results\VIP\Rad
    


    Paths can be set individually for each organisation if requested from within the contact configuration.

    Note

    If the folders do not exist you must create them.

    Make sure the Results folder has Modify, Read and Write permissions, AND is shared on the Network.


  6. Select Message Src Exceptions from the left hand panel of the Capricorn configuration window.
    Image Removed
    Image Added

  7. Click Add as shown above, and select Lookup Sending Facility HD. Do not use any other selection.



  8. A new window will appear called Select Identifier.


     
  9. Enter Southern and press Enter or click the Lightning Bolt to search.

  10. Select Southernex Imaging from the display panel.
     
  11. The following Message Source Exception window will appear.



  12. Click OK to leave all the details blank.

  13. Repeat this step for each of the Contacts that are to be set up in VIP (e.g. In this case QHPS (Nata 2639) and Southernex Imaging).

  14. The configuration is complete. Click Apply and OK.

VIP.net Configuration

  1. Open VIP.net, and click on ‘Setup’‘Practice preferences’ and select ‘General Preferences’.


     

  2. Select the ‘Communications’ tab. Under ‘Batching’, Select ‘Medical-Objects’, and Click the ‘Details’ button.


     

  3. Here you can set the Incoming and Outgoing directory – use UNC Paths for both, for the paths we set up earlier. For example
     

    \\MO\Results\Incoming

    \\MO\Results\Outgoing

     


Receiving Lab Results


If the site receives results from multiple Radiology and Pathology providers, VIP needs to have those Radiology and Pathology organisations created.


  1. Press F2 to open the following window.


     

  2. Type the name of the organisation, select ‘Organisation’ from the right hand panel and click Search.
     

  3. If the organisation doesn’t exist, tick ‘new organisation’ to create it.
     



  4. On the screen that appears, Go to the Investigations Provider Details tab, and click ‘File Transfer’.






    Set the receiving directory to the file path created earlier unless specified otherwise. Use UNC Paths.

    \\MO\Results\VIP\Path Rad

    The Outgoing path is for acknowledgments. Set this path to:

    \\MO\Results\VIP\Outgoing

    And check the box that says "Acknowledge Incoming Messages".

     

    The Lab identifier is used to differentiate results from different companies. If the site receives from more than one Pathology/Radiology Organisation, you may need to set this option. This should be unique to each lab, located in the first line of the result.
     

  5. Make sure ‘Automatically match orders to results’, and HL7 are ticked. Please note that the HL7 button is off by default.


     

Viewing Reports

To View reports, Press F4, and look to the bar on the right side of the VIP interface. Under Communication Type, Tick ‘Incoming’‘Correspondence’ and ‘Referral’.

 



To manually import results go to FileCommunications, and select Services. Select Medical-Objects, and select Proceed.