Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Overview

This guide provides instruction on configuring both Medical-Objects Capricorn and MedTech Evolution to import electronic results.

If you require any assistance with the installation or configuration, or if you have any questions, please contact the Medical-Objects Helpdesk on (07) 5456 6000.

If you have not Installed the Medical-Objects Download client, Please see the guide for Installing Capricorn on Windows.

Configuring Capricorn Software 

Accessing the Capricorn Configuration Window
 


Excerpt Include
How to access Capricorn Configuration
How to access Capricorn Configuration
nopaneltrue

Capricorn Configuration Settings

  1. Click on the Integration Options field on the left hand side.
    Image Removed
    Image Added

  2. Set the Ack Management path paths to the local import folder on the server or the network path on a workstation that points to the server import folder, For example:

    No Format
    Folder for ACKs created by this practices PMS (Receivers)
    (Capricorn installed on the server) --> C:\Medtech32MODemo\AcksCapricorn\APPLICATION_ACKS
    
    Tick Export Application ACKs
    Folder to save external ACKs for PMS (Senders only)
    (Capricorn installed on the Workstationserver) --> C:\MODemo\server\Medtech32\Acks\Capricorn\INCOMING
    
    Note: A Capricorn installed on a Workstation will require a shared paths.


  3. Click on Server Parameters in the left hand side panel.

     Image RemovedImage Added

  4. Under the Message Output Directory (Main) set the results import path.

    No Format
    (Capricorn installed on the server)      --> C:\MODemo\Medtech32Capricorn\HL7INCOMING\In
    
    (Note: A Capricorn installed on thea Workstation) --> \\server\Medtech32\HL7\In will require a shared path.
    


  5. Click Apply / OK. Capricorn configuration is complete.

MedTech32 Configuration

  1. Open the MedTech32 software. In the toolbar, Select Tools > Message Transfer > Message Transfer Utility.



  2. Select the Add New Configuration button highlighted below.

  3. This will open the New Configuration window. In  Description, Type Medical-Objects. make sure that the File Format is set to HL7(H).

  4. You will want to configure the file paths to the correct folder:

    No Format
    File Recieved Path:       -->  C:\Medtech32\HL7\In
    Received File backup Path -->  C:\Medtech32\HL7\Bac
    Rejected File Backup Path -->  C:\Medtech32\HL7\Reje

     

    For Medtech Evolution, Please use the C:\Mo\Results\... directory. Make sure you are using UNC paths. 

    No Format
    File Recieved Path        -->  \\server\Mo\Results\In
    Received File backup Path -->  \\server\Mo\Results\Bac
    Rejected File Backup Path -->  \\server\Mo\Results\Reje


    Done correctly, It should look like the image below. 


  1. You should see Medical-Objects in the Message Transfer Utility List. Click the process button to import.



Viewing Imported Results

Module → Inbox → Provider Inbox

Choose the filter button and set the date range and Attention field (it may be best to set this to "All(*)").

Table of Contents
outlinetrue
stylenone