This guide provides instruction on configuring both Medical-Objects Capricorn and MedTech Evolution to import electronic results.

If you require any assistance with the installation or configuration, or if you have any questions, please contact the Medical-Objects Helpdesk on (07) 5456 6000.

If you have not Installed the Medical-Objects Download client, Please see the guide for Installing Capricorn on Windows.

Configuring Capricorn Software 

Accessing the Capricorn Configuration Window
 

Info
titleNote:

In some cases, the Capricorn may be configured as a service. See this guide for instructions on how to launch the Capricorn if it is set up as a service. 


Excerpt Include
How to access Capricorn Configuration
How to access Capricorn Configuration
nopaneltrue

Capricorn Configuration Settings

  1. Click on the Integration Options field on the left hand side Ack Management.
    Image Removed
    Image Added

  2. Set the Ack ACK Management paths to the local import folder on the server or the network path on a workstation that points to the server import folder, For for example:

    No Format
    Folder for ACKs created by this practices PMS (Receivers)
    (Capricorn installed on the server) --> C:\MODemoMO\Capricorn\APPLICATION_ACKS
    
    Tick Export Application ACKs
    Folder to save external ACKs for PMS (Senders only)
    (Capricorn installed on the server) --> C:\MODemoMO\Capricorn\INCOMING
    
    Note: A Capricorn installed on a Workstation will require a shared pathspath.


  3. Click on Integration Options.
    3.1 Check that the Incoming Modifier is set to Medtech EVO.

     Image Added

  4. Next, click on Server Parameters in the left hand side panel.

     Image Removed
    Under the Message Output Directory (Main) set the results import path.
    No Format
    (Capricorn installed on the server)      --> C:\MODemo\Capricorn\INCOMING\
    
    Note: A Capricorn installed on a Workstation will require a shared path.
    
    Image Added

  5. Then, select Report Scanning field on the left hand side and ensure that Images Only is selected Leave Report scanning as default so images are detached.

    Image Modified

  6. Tick Detach RTF Display Segments (Default)
    Untick Detach PDF Display Segments
    Untick Detach HTML Display Segments
    Tick Convert MDM to ORU with a PDF segment for MDM incompatible PMSs (Default)

  7. Click Apply / OK. Capricorn configuration is complete.
MedTech32

MedTech Configuration

  1. Open the MedTech32 software. In the toolbar, Select select Tools > Message Transfer > Message Transfer Utility.



  2. Select the Add New Configuration button highlighted below.

  3. This will open the New Configuration window. In  Descriptionthe Description field, Type type Medical Objects. make sure that the File Format is set to HL7(H).


  4. Excerpt


    Warning
    titleImportant!
    Tick "Only HL7 PDF outbound" (MedTech Evo Version 10.4.5 with a hotfix or 10.4.6 is required )


    You will also want to configure the file paths to the correct folder:

    No Format
    File Receive Path:       -->  C:\
MODemo
  1. MO\Capricorn\INCOMING
    File Send Path:          -->  C:\
MODemo
  1. MO\Capricorn\SENDING
    Received File backup Path -->  C:\
MODemo
  1. MO\Capricorn\INCOMING\Backup
    Rejected File Backup Path -->  C:\
MODemo
  1. MO\Capricorn\INCOMING\Rejected
    Medical Objects Practice Name = Capricorn Configuration --> Practice Identifiers --> Practice Identifier --> NameSpace ID
    Medical Objects Id = Capricorn Configuration --> Practice Identifiers --> Practice Identifier --> Universal ID
    Medical Objects Id Type = Capricorn Configuration --> Practice Identifiers --> Practice Identifier --> Universal ID Type
    
    Note: A Capricorn installed on a Workstation will require a shared path.


  2. You should see Medical-Objects in the Message Transfer Utility List. Click the

    process

    Process button to import.

    Image Modified


Info
titleNote:

MedTech support will need to configure the automatic interval of results. Contact them to ensure this has been done.

Viewing Imported Results

Module → Inbox → Provider Inbox

Choose the filter Filter button and set the date range and Attention field (it may be best to set this to "All(*)").