Overview:

This guide provides instruction on configuring the Medical-Objects Download Client (Capricorn) to output HL7 Results to a set folder.

If you require any assistance with the installation or configuration, or if you have any questions, please contact the Medical-Objects Helpdesk on (07) 5456 6000.

If you have not Installed the Medical-Objects Download client, Please see the guide for Installing Capricorn on Windows.

Configuring Capricorn Software 

Accessing the Capricorn Configuration Window
 


Excerpt Include
PUB:How to access Capricorn ConfigurationPUB:
How to access Capricorn Configuration
nopaneltrue

Capricorn Configuration Settings

  1. Click on Integration Options.
    Image Removed
    Image Added

  2. Set the ACK Management path to C:\MO\Capricorn\APPLICATION_ACKS.


  3.  Set the Incoming Modifier to Capricorn Modifier as shown above.

  4. Click on Server Parameters in the left pane.



  5. Under the Message Output Directory (main), set the results import path.

    The path will be a folder you want to use to store the Hl7 results or messages that you receive.

    For this installation we will just create a folder in the C: drive called Medical Results.
    The file path in this case will be C:\Medical Results. 
     

  6. Press the Apply button when configurations are complete. All future messages will be delivered to this folder in HL7 format.