This guide provides instruction on configuring both Medical-Objects Capricorn and Audit4 software to import electronic results.

If you require any assistance with the installation or configuration, or if you have any questions, please contact the Medical-Objects Helpdesk on (07) 5456 6000.

If you have not Installed the Medical-Objects Download client, Please see the guide for Installing Capricorn on Windows.

Configuring Capricorn Software 

Accessing the Capricorn Configuration Window
 

Info
titleNote:

In some cases, the Capricorn may be configured as a service. See this guide for instructions on how to launch the Capricorn if it is set up as a service. 


Excerpt Include
How to access Capricorn Configuration
How to access Capricorn Configuration
nopaneltrue

Capricorn Configuration Settings

  1. Click on Ack Management.

     
  2. Set the ACK Management Receivers path as below: 

    No Format
    (Capricorn installed on an Audit 4 Server machine ) -->		C:\Inpath\MO\ACKs\ACKsOutgoing
    
    (Capricorn installed on an Audit 4 client machine --> 		\\Server\Inpath\MO\ACKs\ACKsOutgoing

    2.1 Check Export Application Acks

    2.2 Set the ACK Management Senders Only path as below: 

    No Format
    (Capricorn installed on an Audit 4 Server machine ) -->		C:\Inpath\MO\Acks\AcksIncoming
    
    (Capricorn installed on an Audit 4 client machine --> 		\\Server\Inpath\MO\Acks\AcksIncoming


    Info
    titleNote:

    If the folder does not exist, you must create it. 


  3. Click on Integration Options.

    3.1 Check that the Incoming Modifier is set to Audit4.


     
  4. Select Server Parameters from the left panel.



  5. The paths above are set as follows:

    No Format
    (Capricorn installed on an audit 4 server machine) --> 
    
    Message output directory						C:\Inpath\MO\Letters
    Save pathology:									C:\Inpath\MO\Labs
    Save Radiology:									C:\inpath\mo\Labs
    
    Capricorn installed on an Audit4 Client machine -->
    Message output directory 						  \\Server\Inpath\MO\Letters
    Save Pathology 									  \\Server\Inpath\MO\Labs
    Save Radiology 									  \\Server\Inpath\MO\Labs


  6. Make sure that Save All ORU In Pathology path is UNTICKED.




    Info
    titleNote:

    If the folder does not exist, you must create it.


    Info
    titleNote:

    It is important that these folders only exist on one PC (Usually always the server) as they can cause conflicts.


  7. Complete the Manage Queues section below.

Current Manage Queues

Multiexcerpt include
MultiExcerptNameAUDIT4 OUTGOING REF
PageWithExcerptManage Queues

Historical Manage Queues

Multiexcerpt include
MultiExcerptNameAUDIT 4 INCOMING LETTERS ORU TO REF
PageWithExcerptManage Queues

Multiexcerpt include
MultiExcerptNameAUDIT4 OUTGOING RRI TO ACK
PageWithExcerptManage Queues

Software for Specialists (Audit4) Configuration.


You will need to contact the Software4Specialist Help-Desk so that they can configure Audit4 to Import the Letters and Lab results and the export of Acknowledgments.


No Format
Department: Support
Contact Number: 1300 133 308
Organisation: Software for Specialists (Audit4)


Audit4 will require the following Configuration: 

  1. Letters are to be imported from: C:\Inpath\MO\Letters
     
    Previously this was the path defined by the Convert Letters to REF queue’s Store Message in folder decorator.
     
  2. Lab results are to be imported from: C:\Inpath\MO\Labs
     
  3. Acknowledgements are to be exported to: C:\Inpath\MO\ACKs\ACKsOutgoing

    Previously this was the path defined by the Base directory for the ConvertACK Queue.


(Capricorn installed on a Audit4 Server Machine) -->

i.      Store Message in Folder:              C:\Inpath\MO\Acks
 
(Capricorn installed on a Audit4 Client Machine) --> 
 
ii.     Store Message in Folder:              \\Server\Inpath\MO\Acks


19.  Click Apply and OK to save the Convert Acks Queue and return to the Managed Queue configuration Screen.

20. Click Apply and OK to save the current configuration and to exit the Capricorn configuration editor.

You have now completed the configuration for the Medical Objects Capricorn to download and send acknowledgements.