Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Overview

This guide will instruct you provides a basic overview on how to set up configure the Medical-Objects Download Client (Capricorn) to import drop off results for CompuDoc softwareCompudoc software.

If you require any assistance with the installation or configuration, or if you have any questions, please contact the Medical-Objects Helpdesk on (07) 5456 6000.

If you have not Installed the Medical-Objects Download client, Please see the guide for Installing Capricorn on Windows.

Finding the CompuDoc File path

  1. Open Compudoc on the server, and choose Tools, and then click Options.
     

     
  2. Click on the Locations box on the right hand side.


     
  3. Here you can see the file path that CompuDoc is set to pick up the results from. 

Configuring the Capricorn


Accessing the Capricorn Configuration Window

 

Double click the HL7 tray icon.
Image Removed
The log window is displayed.
Image Removed



Excerpt Include
How to access Capricorn Configuration
How to access Capricorn Configuration
nopaneltrue

Capricorn Configuration Settings

 

Click the Edit Server Properties icon.
Image Removed

  1. Click on Integration Options in the left hand side panel.



    Tick the boxes Convert to PIT and Preserve Sending Facility in PIT.
    Make sure the Incoming Modifier is set to Capricorn Modifier.
    The Ack Management path should be set to C:\MO\Capricorn\APPLICATION_ACKS.
     
  2. Click on Server Parameters in the left hand panel.



    The Message Output Directory to the import directory for CompuDoc outlined in the previous instructions. For this example, we’ll use C:\Compudoc\Pathology.


    The configuration is complete. Compudoc should automatically begin importing results.

 

Table of Contents
outlinetrue
stylenone