Overview
This guide provides instructions on configuring both Medical-Objects Capricorn and Practix software to import electronic results.
If you require any assistance with the installation or configuration, or if you have any questions, please contact the Medical-Objects Helpdesk on (07) 5456 6000.
If you have not Installed the Medical-Objects Download client, Please see the guide for Installing Capricorn on Windows.
Configuring Capricorn Software
Accessing the Capricorn Configuration Window
 
| Excerpt Include | ||||||
|---|---|---|---|---|---|---|
| 
 | 
Integration Options
- From the left hand panel, Select Integration Options. 
 
- Set the Folder for ACKS to the folder Practix will be outputting them to - Typically C:\msp\resultsimport\ACKs. The same import path will need to be added to a contact in Practix, outlined later in this guide. 
 
- Make sure at the bottom of the panel that under Incoming Modifier, The Practix HL7 Modifier is set as shown below. 
  Image Added Image Added- Image Removed 
Report Scanning
- In the left hand panel, Select Report Scanning. 
- In the Report Scanning window, set the path to create a MO-Images folder in the same path as the ACKs folder as shown below. 
  
- Once you have typed in the path, a message window will pop up and ask if you want to create the path. 
  
- Select OK to create the path. 
Message Source Exceptions
- Select Message Src Exceptions from the left hand panel of the Capricorn configuration window. 
  
- Click Add as shown above, and select Lookup Sending Facility HD. Do not use any other selection. 
  
- A new window will appear called Select Identifier.  
 
- Enter Southern and press Enter or click the Lightning Bolt to search. 
 
- Select Southernex Imaging from the display panel. 
 
- The following Message Source Exception window will appear. 
  
- Click OK to leave all the details blank. 
 
- Repeat this step for each of the Pathology and Radiology sites that send to the Practice.(e.g. In this case QHPS (Nata 2639) and Southernex Imaging). 
Server Parameters
- In the left hand side panel, select Server Parameters.
 
- In Message Output Directory (main) Enter the path for the Download client to drop off results to. Typically, this is C:\msp\resultimport.  
Practix Configuration
Adding a Contact for Medical-Objects
- Open up the Practix Software. 
  
- Click Administration. 
 
- Select System Configuration then select Contacts and Contacts again.  
 
- Click Enter.
- Once you have clicked Enter the following window will appear.
  
- Perform a search for Medical-Objects. If the entry exists, click on Medical-Objects and then click Select, otherwise click New to create it.  
 
- Select Company and then enter in the details shown in the above window. 
- Click the Messages In button on the right hand side.
 
- Once you click Messages In, the following window will appear.  
- Enter details the from the above image.
- Once you get to the Message Details area, click on the Add button highlighted on the right hand side. 
- Once you have clicked Add, the following window will appear. 
  
- Select ORU^R01-Result as the Message Type then Click OK.
 
- Click Save on the Receive Message From window. 
 
- Click Close on the Receive Message From window. 
 
- Click OK on the Contact window. 
 
- Click Close on the Find Contact window.
Adding a Radiology Contact
- Perform a search for the Radiology sending facility you are about to add. For example, Southern X-ray. If the Facility exists; click the name and click Select, otherwise click New to create it. 
- Select Company and then enter in the companies details. When you are finished, click Message In.  
- Once you have clicked the Message In button, the following window will appear.  
- Enter the Radiology Company’s details as shown above. (The drive letter and path may vary depending on the folder location that the practice has designated for imports).
 
- Click Add to setup the receiving type.
- Select the ORU^R01-Result as the Message Type then Click OK.
  
- Click Save on the Receive Message From window 
 
- Click Close on the Receive Message From window 
 
- Click OK on the Contact window 
 
- Click Close on the Find Contact window 
 
Adding a Pathology Contact
- Perform a search for the Pathology sending facility you are about to add. For example, Queensland Health Pathology Services. If the Facility exists; click the name and click Select, otherwise click New to create it.  
- Select Company and then enter in the companies details and then click Message In.  
- Once you have clicked the Message In button the following window will appear.  
- Enter the Pathology Company’s details as shown above. (The drive letter and path may vary depending on the folder location that the practice has designated for imports). - Click Add to setup the receiving type. 
 
- Select the ORU^R01-Result as the Message Type then Click OK. 
  
- Click Save on the Receive Message From window. 
 
- Click Close on the Receive Message From window. 
 
- Click OK on the Contact window. 
 
- Click Close on the Find Contact window. 
The configuration for Practix is now completed.