Overview:
This guide provides instruction on configuring both Medical-Objects Capr=
icorn and Monet software to import electronic results.
If you require any assistance with the installation or configuration, or i=
f you have any questions, please contact the Medical-Objects Helpdesk on (0=
7) 5456 6000.
If you have not Installed the Medical-Objects Download client, Please see =
the guide for Installing Capricorn on Windows.
Configuring Capricorn Softwar=
e
Accessing the Cap=
ricorn Configuration Window
- To launch the HL7 Tray application, Go to Start Menu, All Progr=
ams, Medical-Objects and select the Medical-Objects Capric=
orn. Alternatively, You can go to C:\MO\Capricorn=
and run the Capricorn.exe.
- The following icon will appear in the tray. Double click on it to bring=
up the log window.
=
li>
- When the log window is displayed, Click on the Configuration icon highlighted below, or select Utility and selec=
t Configuration.
Capricorn Configuration Set=
tings
- Click on Ack Management.
- Set the Ack path to C:\MO\Capricorn\APPLICATION_ACKS
- Click on Integration Options.
3.1 Check that the Incoming Modifier is set to Mo=
net
- Select Server Parameters from the left hand panel.&nbs=
p;
Enter the path to drop off results to - for this exampled we'll use =
C:\Pit\Hold
If receiving from Pathology and Radiology, Set the file paths as follows.&=
nbsp;
Pathology --> C:\Pit\Path
Radiology --> C:\Pit\Img
- Click Apply and OK to save your confi=
guration.
Configuring Monet
- To access the result input configurations go to the =E2=80=98Mo=
net palette=E2=80=99 window of Monet.
- Click on the Check Result Icon in the left pane.
- Click on the Configure Button shown below.
- The results input path screen will be displayed.
Importing Patholog=
y & Radiology Results
- Open Monet, and from the Palette scre=
en, click the Check Results button to open the Check Results screen.
- Click the PIT tab and then click the Chec=
k button to import the new results into Monet.
- The PIT Pathology Results message box will appear=
advising that the results have been imported. Click the OK button.
- Repeat steps 1-3 for each Pathology and Radiology company from the exte=
rnal downloading software.
- Each pathology & radiology company data must be downloaded and subs=
equently imported into the Check Results screen one c=
ompany=E2=80=99s group of results at a time. Do not combine the proces=
s of downloading the data for each company and then attempt to import them =
together.
- The imported results will display in the Check Results=
screen. The results will automatically match to a Patient if all the Patie=
nt=E2=80=99s details within the result file (the. pit file) match the Patie=
nt=E2=80=99s demographics in Monet.
- Where the imported results cannot match to a Patient=E2=80=99s file, a =
red cross will be displayed in the Match column.
- Click the Match button on the top toolbar to display t=
he Patient Match screen.
- Type in the Patient=E2=80=99s name to perform the search and then click=
the Match Again button.